TM 9--2350--292--10
0101 00--12
PREVENTIVE MAINTENANCE CHECKS AND SERVICES INCLUDING
LUBRICATION INSTRUCTIONS -- CONTINUED
0101 00
TABLE 1 PREVENTIVE MAINTENANCE CHECKS AND SERVICES, BEFORE--CONTINUED
Item No.
Not Fully Mission
Capable If:
CREWMEMBER
Procedure
LOCATION
Item to Check/
Service
Interval
COMMANDER
9
Before
Portable
Fire Extin-
guishers
a. Check portable fire extinguishers control
seals. Make sure seals or locking wires are
not broken.
a. Any fire
extinguisher missing.
Seal or lockwire
missing or broken.
b. Check fire extinguishers for security of
mounting hardware and missing hardware.
c. Check inspection tags for current
inspection date of cylinders.
b. Inspection tag not
current.
NOTE
Refer to TM 11-5820-890-10
(AN/VIC--1(V) or TM 11--5830--263--10
(AN/VIC--3(V) and TM 11-5830-340-12
for radio operational checks.
10
Before
Intercommunica-
tions System
and Radio Sets
a. Check intercommunication system
operation.
b. Check for unusual noises, interference
or poor operation in general. Report all
problems to unit maintenance.
No means of
communication
between driver and
commander.