TM 9--2350--292--20--1
0255 00--2
CURRENT SHUNT REPLACEMENT -- CONTINUED
0255 00
NOTE
Tag all electrical connections and electrical leads prior to
removal to aid in installation.
Removal
1. Remove two screws (1), two lockwashers (2) and three lead assemblies 3W209 (3, 4 and 5). Discard
lockwashers.
2. Remove two screws (6), two flat washers (7), two lockwashers (8) and wiring harness 3W801 wires X and Y (9
and 10). Discard lockwashers.
3. Remove two screws (11), two lockwashers (12) and three lead assemblies 3W210--1, --2 and --3 (13, 14 and 15).
Discard lockwashers.
4. Remove four screws (16), four flat washers (17), four lockwashers (18) and shunt (19). Discard lockwashers.
5. Inspect parts for damage and replace as required.
Figure 72
1
2
4
5
1
3
19
6
8
7
9
6
8
7
10
11
12
13
11
12
14
15
16
18
17
2