TM 9--2350--292--20--10039 00--5PURGE PUMP FAILS TO OPERATE (PURGE PUMP CANNOT BE HEARDOPERATING WHEN TURNED ON) -- CONTINUED0039 00Is continuity present?1. Remove switch panel (WP 0242 00), reconnectground lead and disconnect lead 10 from CB3.2. Place one multimeter lead on switch panelreceptacle pin E and other lead in lead 10circuit breaker connector socket. Check forcontinuity.KnoyesRepair (WP 0290 00) or replace(WP 0242 00) lead 10 fromswitch panel connector to CB3.Verify fault is corrected.CONTINUED FROM STEP JIs continuity present?1. Disconnect lead 76 from CB3.2. Place one multimeter lead on each connectorend of fuel pump circuit breaker. Check forcontinuity.noyesLIs continuity present?1. Reconnect lead 10 to CB3.2. Disconnect lead 76 from CB3 side of switch S4.3. Place one multimeter lead in lead 76 CB3connector socket and other lead in lead 76switch S4 connector socket. Check forcontinuity.MReplace CB3 (WP 0242 00).Verify fault is corrected.noyesRepair (WP 0290 00) or replace(WP 0242 00) lead 76. Verifyfault is corrected.CONTINUED ON NEXT PAGE