TM 9--2350--292--20--1PURGE PUMP FAILS TO OPERATE (PURGE PUMP CANNOT BE HEARDOPERATING WHEN TURNED ON) -- CONTINUED0039 00Is 24 V dc present?1. Reconnect lead 76 to switch S4.2. Remove subfloor plate 20 (WP 0454 00).3. Disconnect harness 4W101 P5 from fuel pump.4. Turn MASTER switch ON and FUEL PUMPswitch to PURGE (TM 9--2350--292--10).5. Place multimeter red lead in harness 4W101 P5socket at fuel pump and black lead to ground.Check for voltage.6. Turn MASTER switch and FUEL PUMP switchOFF (TM 9--2350--292--10).PnoyesReplace harness 4W101(WP 0315 00). Verify fault iscorrected.CONTINUED FROM STEP I AND OIs continuity present?Place one multimeter lead in ground socket ofharness 4W101 P5 and other lead to ground.Check for continuity.QnoyesReplace fuel pump(WP 0201 00). Verifyfault is corrected.Replace fuse (WP 0201 00).Verify fault is corrected.Is continuity present?1. Remove fuse block from fuel pump(WP 0201 00).2. Remove fuse from fuse block (WP 0201 00)and place one multimeter lead on each endof fuse. Check for continuity.RnoyesReplace ground lead.Verify fault is corrected.END OF TASK0039 00--7/8 blank