TM 9--2350--292--20--10041 00--3ENGINE FAILS TO CRANK WHEN STARTER SWTICH IS PRESSED --CONTINUED0041 00CONTINUED ON NEXT PAGEPerform STE--ICE--R test 68(TM 9--4910--571--12&P) and record results.noyesHIs VTM reading at least 18 V dc?CONTINUED FROM STEP F AND GPerform STE--ICE--R test 69(TM 9--4910--571--12&P) and record results.noyesIIs VTM reading higher than 1.8 V dc?Run test 67 with function 02(TM 9--4910--571--12&P).If test passes, repair (WP0290 00) or replace (WP0333 00) harness 4W800.Verify fault is corrected.Perform STE--ICE--R test 70(TM 9--4910--571--12&P) and record results.noyesJIs VTM reading at least 18 V dc?Repair (WP 0290 00) orreplace (WP 0333 00)harness 4W800. Verifyfault is corrected.Replace engine starter(WP 0240 00). Verifyfault is corrected.