TM 9--2350--292--20--10039 00--2PURGE PUMP FAILS TO OPERATE (PURGE PUMP CANNOT BE HEARDOPERATING WHEN TURNED ON) -- CONTINUED0039 00Does fuel flow freely from check valve?1. Reconnect fuel line to OUT port of purge pump.2. Disconnect fuel outlet hose from main enginefuel check valve.3. Place container under check valve and turnMASTER switch ON and FUEL PUMP switch toPURGE (TM 9--2350--292--10).4. Hold ENGINE PREHEAT switch in PURGEposition (TM 9--2350--292--10).5. Turn MASTER switch and FUEL PUMP switchOFF (TM 9--2350--292--10).noyesDCan purge pump be heard operating?1. Turn MASTER switch ON and FUEL PUMPswitch to PURGE (TM 9--2350--292--10).2. Place ENGINE PREHEAT switch in ON position(TM 9--2350--292--10) and listen for purge pumpto operate.3. Turn MASTER switch and FUEL PUMP switchOFF (TM 9--2350--292--10).EnoyesGo to step I.CONTINUEDFROMSTEPCFault corrected.Replace main enginecheck valve (WP 0225 00).Verify fault is corrected.CONTINUED FROM STEP BReplace purge pump(WP 0225 00). Verifyfault is corrected.noyesCONTINUED ON NEXT PAGE