TM 9--2350--292--20--1
0070 00--4
ALL SIGNALS AT REMOTE TERMINAL UNIT CONNECTOR J5 ARE BELOW
VALID RANGE OR OPEN -- CONTINUED
0070 00
FROM
TO
CONNECTOR/PIN
CONNECTOR/PIN
P1--a
P8--1
P1--b
P8--2
P1--c
P8--3
P1 Backshell
P8 Backshell
P1--d
P9--1
P1--e
P9--2
P1--f
P9--3
P1 Backshell
P9 Backshell
P1--g
P10--1
P1--h
P10--2
P1--i
P10--3
P1 Backshell
P10 Backshell
P1--w
P11--A
P1--x
P11--B
P1--y
P11--C
P1 Backshell
P11 Backshell
CONTINUED FROM STEP C
D
yes
no
Repair (WP 0290 00) or
replace (WP 0681 00)
wiring harness 4W506.
Verify fault is corrected.
Replace remote
terminal unit (WP
0675 00). Verify
fault is corrected.
Is
continuity
present at all checks?
END OF TASK