Home
Download PDF
Order CD-ROM
Order in Print
ALL SIGNALS AT REMOTE TERMINAL UNIT CONNECTOR J3 ARE BELOW VALID RANGE OR OPEN cont)
ALL SIGNALS AT REMOTE TERMINAL UNIT CONNECTOR J5 ARE BELOW VALID RANGE OR OPEN (cont) - TM-9-2350-292-20-1_332
TM-9-2350-292-20-1 Carrier Ammunition Tracked M992A1(NSN 2360-01-362-3021) EIC:AE6 Manual
Page Navigation
282
283
284
285
286
287
288
289
290
291
292
TM 9--2350--292--20--1
ALL SIGNALS AT REMOTE TERMINAL UNIT CONNECTOR J3 ARE BELOW
VALID RANGE OR OPEN -- CONTINUED
0069 00
CONTINUED FROM STEP C
FROM
TO
CONNECTOR/PIN
CONNECTOR/PIN
P1--g
P12--1
P1--h
P12--2
P1--i
P12--3
P1 Backshell
P12 Backshell
P1--k
P10--1
P1--m
P10--2
P1--n
P10--3
P1 Backshell
P10 Backshell
P1--w
P11--1
P1--x
P11--2
P1--y
P11--3
P1 Backshell
P11 Backshell
P1--s
P13--1
P1--t
P13--2
P1--u
P13--3
P1 Backshell
P13 Backshell
E
Is
continuity
present at all checks?
yes
no
Repair (WP 0290 00) or
replace (WP 0679 00)
wiring harness 4W503.
Verify fault is corrected.
Replace remote
terminal unit (WP
0675 00). Verify
fault is corrected.
END OF TASK
0069 00--5/6 blank
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business