Google+
Facebook
LinkedIn
Twitter
Digg
StumbleUpon
Home
Download PDF
Order CD-ROM
Order in Print
ALL SIGNALS AT CABLE ASSEMBLY 4W504 CONNECTOR J1 ARE BELOW VALID RANGE OR OPEN (cont) - TM-9-2350-292-20-1_325
ALL SIGNALS AT REMOTE TERMINAL UNIT CONNECTOR J3 ARE BELOW VALID RANGE OR OPEN (cont) - TM-9-2350-292-20-1_327
TM-9-2350-292-20-1 Carrier Ammunition Tracked M992A1(NSN 2360-01-362-3021) EIC:AE6 Manual
Page Navigation
277
278
279
280
281
282
283
284
285
286
287
TM 9--2350--292--20--1
ALL SIGNALS AT CABLE ASSEMBLY 4W504 CONNECTOR J1 ARE BELOW
VALID RANGE OR OPEN -- CONTINUED
0068 00
CONTINUED FROM STEP C
FROM
TO
CONNECTOR/PIN
CONNECTOR/PIN
P1--Y
P4--1
P1--Z
P4--2
P1--a
P4--3
P1--Backshell
P4--Backshell
P1--c
P5--1
P1--d
P5--2
P1--e
P5--3
P1--Backshell
P5--Backshell
P1--g
P6--1
P1--h
P6--2
P1--l
P6--3
P1--Backshell
P6--Backshell
P1--k
P7--1
P1--m
P7--2
P1--n
P7--3
P1--Backshell
P7--Backshell
P1--o
P8--1
P1--r
P8--2
P1--s
P8--3
P1 Backshell
P8 Backshell
F
Is
continuity
present at all checks?
yes
no
Repair (WP 0290 00) or
replace (WP 0676 00)
wiring harness 2W505.
Verify fault is corrected.
Replace remote termi-
nal unit (WP 0675 00).
Verify fault is cor-
rected.
END OF TASK
0068 00--5/6 blank
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business