TM 9--2350--292--20--10119 00--5BLACKOUT STOPLIGHTS FAIL TO OPERATE -- CONTINUED0119 00noyesRepair (WP 0290 00) orreplace (WP 0242 00)harness 4W151. Verifyfault is corrected.IJ1. Disconnect harness 4W127 P2 from switchpanel.2. Place one multimeter lead on harness 4W151J2 pin C and other lead in harness 4W151 P1socket N. Check for continuity.Is continuity present?Is continuity present at both checks?CONTINUED FROM STEP HnoyesRepair (WP 0290 00) orreplace (WP 0317 00)harness 4W105. Verifyfault is corrected.K Place one multimeter lead in harness 4W105 P1socket L and other lead in lead 75 and 75/16 con-nector socket (one at a time). Check for continu-ity.Is continuity present at one or both checks?noyesRepair (WP 0290 00) orreplace (WP 317) harness 4W105.Verify fault is corrected.1. Reconnect harness 4W151 P1 to switch S8.2. Disconnect lead 75 and 75/16 stoplightswitch.3. Place one multimeter lead in harness 4W105P1 socket D and other lead in lead 75 and75/16 connector socket (one at a time).Check for continuity.CONTINUED ON NEXT PAGE