TM 9--2350--292--20--1TURN SIGNAL FAILS TO OPERATE -- CONTINUED0118 00CONTINUED FROM STEP NO 1. Disconnect harness 4W105 P1 from switchpanel.2. Place one multimeter lead on harness 4W151J4 pin N and other lead in harness 4W151 P1socket F. Check for continuity.Is continuity present?noyesRepair (WP 0290 00) orreplace (WP 0242 00)harness 4W151. Verifyfault is corrected.noyesRepair (WP 0290 00) orreplace (WP 0314 00)harness 4W100. Verifyfault is corrected.P1. Turn MASTER switch ON(TM 9--2350--292--10).2. Place multimeter red lead in harness 4W105P1 socket N and black lead to ground. Checkfor voltage.3. Turn MASTER switch OFF(TM 9--2350--292--10).Is 24 V dc present?Replace light switch(WP 0242 00). Verifyfault is corrected.END OF TASK0118 00--7/8 blank
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business