TM 9--2350--292--20--1
TURN SIGNAL FAILS TO OPERATE -- CONTINUED
0118 00
CONTINUED FROM STEP N
O 1. Disconnect harness 4W105 P1 from switch
panel.
2. Place one multimeter lead on harness 4W151
J4 pin N and other lead in harness 4W151 P1
socket F. Check for continuity.
Is continuity present?
no
yes
Repair (WP 0290 00) or
replace (WP 0242 00)
harness 4W151. Verify
fault is corrected.
no
yes
Repair (WP 0290 00) or
replace (WP 0314 00)
harness 4W100. Verify
fault is corrected.
P
1. Turn MASTER switch ON
(TM 9--2350--292--10).
2. Place multimeter red lead in harness 4W105
P1 socket N and black lead to ground. Check
for voltage.
3. Turn MASTER switch OFF
(TM 9--2350--292--10).
Is 24 V dc present?
Replace light switch
(WP 0242 00). Verify
fault is corrected.
END OF TASK
0118 00--7/8 blank