TM 9--2350--292--20--1
0118 00--6
TURN SIGNAL FAILS TO OPERATE -- CONTINUED
0118 00
no
yes
Repair (WP 0290 00) or
replace (WP 0324 00)
harness 4W127. Verify
fault is corrected.
M
N
1. Remove switch panel from bracket
(WP 0000 00) and reconnect ground strap to
switch panel.
2. Disconnect harness 4W127 P2 from switch
panel.
3. Turn MASTER switch ON
(TM 9--2350--292--10).
4. Place multimeter red lead on harness 4W151
J2 pin E and black lead to ground. Check for
voltage.
5. Turn MASTER switch OFF
(TM 9--2350--292--10).
Is 24 V dc present?
Is continuity present?
CONTINUED FROM STEP H
no
yes
Repair (WP 0290 00) or
replace (WP 0242 00)
harness 4W151. Verify
fault is corrected.
CONTINUED ON NEXT PAGE
1. Reconnect harness 4W127 P1 to directional
signal control.
2. Disconnect harness 4W151 P1 from switch S8
receptacle.
3. Place one multimeter lead on harness 4W151
J2 pin E and other lead in harness 4W151 P1
socket J. Check for continuity.