TM 9--2350--292--20--10118 00--6TURN SIGNAL FAILS TO OPERATE -- CONTINUED0118 00noyesRepair (WP 0290 00) orreplace (WP 0324 00)harness 4W127. Verifyfault is corrected.MN1. Remove switch panel from bracket(WP 0000 00) and reconnect ground strap toswitch panel.2. Disconnect harness 4W127 P2 from switchpanel.3. Turn MASTER switch ON(TM 9--2350--292--10).4. Place multimeter red lead on harness 4W151J2 pin E and black lead to ground. Check forvoltage.5. Turn MASTER switch OFF(TM 9--2350--292--10).Is 24 V dc present?Is continuity present?CONTINUED FROM STEP HnoyesRepair (WP 0290 00) orreplace (WP 0242 00)harness 4W151. Verifyfault is corrected.CONTINUED ON NEXT PAGE1. Reconnect harness 4W127 P1 to directionalsignal control.2. Disconnect harness 4W151 P1 from switch S8receptacle.3. Place one multimeter lead on harness 4W151J2 pin E and other lead in harness 4W151 P1socket J. Check for continuity.