TM 9--2350--292--20--10119 00--2BLACKOUT STOPLIGHTS FAIL TO OPERATE -- CONTINUED0119 00Is 24 V dc present?1. Disconnect harness 3W142 P1 from bulkheaddisconnect.2. Turn MASTER switch ON(TM 9--2350--292--10).3. Set main light switch to BO DRIVE or BOMARKER (TM 9--2350--292--10).4. While assistant presses brake pedal, placemultimeter red lead in harness 3W142 P1socket C and black lead to ground. Check forvoltage.5. Turn MASTER switch OFF(TM 9--2350--292--10).noyesGo to Step L.CCONTINUED ON NEXT PAGECONTINUEDFROMSTEPB