TM 9--2350--292--20--10131 00--2TURBOCHARGER DUST DETECTOR INDICATOR LIGHT FAILS TO OPERATE-- CONTINUED0131 00Is 24 V dc present?1. Disconnect lead 27 from indicator L2.2. Turn MASTER switch ON(TM 9--2350--292--10).3. Place multimeter red lead in lead 27 lightconnector socket and black lead to ground.Check for voltage.4. Turn MASTER switch OFF(TM 9--2350--292--10).noyesnoyesCDCONTINUED ON NEXT PAGE1. Disconnect harness 4W105 P1 from switchpanel.2. Turn MASTER switch ON(TM 9--2350--292--10).3. Place multimeter red lead on harness 4W105P1 socket N and black lead to ground. Checkfor voltage.4. Turn MASTER switch OFF(TM 9--2350--292--10).Is 24 V dc present?Go to Step J.Repair (WP 0290 00) orreplace (WP 0314 00)harness 4W100. Verifyfault is corrected.CONTINUED FROM STEP B