TM 9--2350--292--20--10131 00--4TURBOCHARGER DUST DETECTOR INDICATOR LIGHT FAILS TO OPERATE-- CONTINUED0131 00HIs continuity present?CONTINUED FROM STEP GnoyesCONTINUED ON NEXT PAGE1. Reconnect lead 25/27 to CB6.2. Disconnect harness 4W103 P1 from gaugepanel.3. Place one multimeter lead on harness 4W105P1 socket K and other lead in harness 4W103P1 socket K. Check for continuity.Repair (WP 0290 00) orreplace (WP 0316 00)harness 4W103. Verifyfault is corrected.IIs continuity present?noyes1. Reconnect harness 4W105 P1 to switch panel.2. Place one multimeter lead on harness 4W152J1 pin K and other lead in lead 27 lightconnector socket. Check for continuity.Repair (WP 0290 00) or re-place (WP 0243 00) lead27. Verify fault is corrected.JIs continuity present?noyes1. Disconnect lead 510 from indicator L2.2. Place one multimeter lead in lead 510 indicatorL2 connector socket and other lead on harness4W152 J1 pin C. Check for continuity.Repair (WP 0290 00) orreplace (WP 0243 00)lead 510. Verify fault iscorrected.CONTINUED FROMSTEP C
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business