TM 9--2350--292--20--1
0131 00--4
TURBOCHARGER DUST DETECTOR INDICATOR LIGHT FAILS TO OPERATE
-- CONTINUED
0131 00
H
Is continuity present?
CONTINUED FROM STEP G
no
yes
CONTINUED ON NEXT PAGE
1. Reconnect lead 25/27 to CB6.
2. Disconnect harness 4W103 P1 from gauge
panel.
3. Place one multimeter lead on harness 4W105
P1 socket K and other lead in harness 4W103
P1 socket K. Check for continuity.
Repair (WP 0290 00) or
replace (WP 0316 00)
harness 4W103. Verify
fault is corrected.
I
Is continuity present?
no
yes
1. Reconnect harness 4W105 P1 to switch panel.
2. Place one multimeter lead on harness 4W152
J1 pin K and other lead in lead 27 light
connector socket. Check for continuity.
Repair (WP 0290 00) or re-
place (WP 0243 00) lead
27. Verify fault is corrected.
J
Is continuity present?
no
yes
1. Disconnect lead 510 from indicator L2.
2. Place one multimeter lead in lead 510 indicator
L2 connector socket and other lead on harness
4W152 J1 pin C. Check for continuity.
Repair (WP 0290 00) or
replace (WP 0243 00)
lead 510. Verify fault is
corrected.
CONTINUED FROM
STEP C