TM 9--2350--292--20--1
0141 00--1
PERSONNEL HEATER FAILS TO IGNITE (HEATER BLOWER OPERATES
PROPERLY).
0141 00
THIS WORK PACKAGE COVERS:
Personnel Heater Fails To Ignite. (Heater Blower Operates Properly).
INITIAL SETUP:
Tools and Special Tools
General mechanics tool kit (item 1, WP 0717 00)
Utility pail (item 27, WP 0717 00)
Personnel Required
Two
Equipment Conditions
Vehicle MASTER switch OFF (TM 9--2350--292--10)
Air particulate filter and bracket removed
(WP 0706 00)
Did fuel run into container?
1. Disconnect fuel line from personnel heater.
2. Place disconnected fuel line into container and
place HEATER CONTROL switch to RUN
position (TM 9--2350--292--10).
3. Place HEATER CONTROL switch to OFF
position (TM 9--2350--292--10).
no
yes
no
yes
A
B
CONTINUED ON NEXT PAGE
1. Remove personnel heater fuel pump shield.
2. Disconnect fuel line from OUT port of fuel filter.
3. Place container under fuel filter and place
HEATER CONTROL switch to RUN position
(TM 9--2350--292--10).
4. Place HEATER CONTROL switch to OFF
position (TM 9--2350--292--10).
Did fuel run into container?
WARNING
Remove rings, bracelets, wristwatches,
and neck chains before working on any
vehicle. Jewelry can catch on equip-
ment and cause injury, or may short
across an electrical circuit and cause
severe burns or electrical shock.
Go to page WP 0140 00.
Clear or replace fuel
line from filter to heater
(WP 0533 00). Verify
fault is corrected.