TM 9--2350--292--20--10141 00--2PERSONNEL HEATER FAILS TO IGNITE. (HEATER BLOWER OPERATESPROPERLY) -- CONTINUED0141 00CDid fuel run into container?CONTINUED FROM STEP BnoyesCONTINUED ON NEXT PAGE1. Reconnect fuel line to personnel heater andpersonnel heater fuel filter OUT port.2. Disconnect fuel line from personnel heater fuelfilter IN port.3. Place disconnected fuel line into container andplace HEATER CONTROL switch to RUNposition (TM 9--2350--292--10).4. Place HEATER CONTROL switch to OFFposition (TM 9--2350--292--10).Replace fuel filter(WP 0534 00). Verifyfault is corrected.DDid fuel run into container?1. Reconnect fuel line to personnel heater fuelfilter IN port.2. Disconnect fuel line from personnel heater fuelpump OUT port.3. Place container under fuel pump and placeHEATER CONTROL switch to RUN position(TM 9--2350--292--10).4. Place HEATER CONTROL switch to OFFposition (TM 9--2350--292--10).noyesClear or replace fuelline from fuel pump tofuel filter (WP 0533 00).Verify fault is corrected.