TM 9--2350--292--20--1
0141 00--2
PERSONNEL HEATER FAILS TO IGNITE. (HEATER BLOWER OPERATES
PROPERLY) -- CONTINUED
0141 00
C
Did fuel run into container?
CONTINUED FROM STEP B
no
yes
CONTINUED ON NEXT PAGE
1. Reconnect fuel line to personnel heater and
personnel heater fuel filter OUT port.
2. Disconnect fuel line from personnel heater fuel
filter IN port.
3. Place disconnected fuel line into container and
place HEATER CONTROL switch to RUN
position (TM 9--2350--292--10).
4. Place HEATER CONTROL switch to OFF
position (TM 9--2350--292--10).
Replace fuel filter
(WP 0534 00). Verify
fault is corrected.
D
Did fuel run into container?
1. Reconnect fuel line to personnel heater fuel
filter IN port.
2. Disconnect fuel line from personnel heater fuel
pump OUT port.
3. Place container under fuel pump and place
HEATER CONTROL switch to RUN position
(TM 9--2350--292--10).
4. Place HEATER CONTROL switch to OFF
position (TM 9--2350--292--10).
no
yes
Clear or replace fuel
line from fuel pump to
fuel filter (WP 0533 00).
Verify fault is corrected.