TM 9--2350--292--20--1
PERSONNEL HEATER FAILS TO KEEP BURNING.
0142 00
THIS WORK PACKAGE COVERS:
Personnel Heater Fails To Keep Burning
INITIAL SETUP:
Tools and Special Tools
General mechanics tool kit (item 1, WP 0000 00)
Equipment Conditions
Vehicle MASTER switch OFF (TM 9--2350--292--10)
Air particulate filter and bracket removed
(WP 0000 00)
Personnel Required
Two
Did fuel flow from fuel line in a steady flow?
1. Loosen (but do not remove) fuel line from
personnel heater.
2. Hold a shop rag around fuel line fitting and
place HEATER CONTROL switch to START
position (TM 9--2350--292--10).
3. Bleed air from fuel line until steady flow of fuel
runs from fuel line.
4. Place HEATER CONTROL switch to OFF
position (TM 9--2350--292--10).
WARNING
Remove rings, bracelets, wristwatches,
and neck chains before working on any
vehicle. Jewelry can catch on equip-
ment and cause injury, or may short
across an electrical circuit and cause
severe burns or electrical shock.
yes
no
Go to WP 0141 00
Step B.
Tighten fuel line. Verify
fault is corrected.
END OF TASK
0142 00--1/2 blank