TM 9--2350--292--20--10179 00--2LEVEL WINDER MALFUNCTION INDICATOR FAILS TO LIGHT WHEN LEVELWINDER MALFUNCTIONS -- CONTINUED0179 00CIs 24 V dc present at both checks?CONTINUEDFROMSTEPBnoyesCONTINUED ON NEXT PAGE1. Turn MASTER switch ON(TM 9--2350--292--10).2. Place multimeter red lead on accessory controlpanel receptacle J1 pin S and H (one at a time)while holding black lead to ground. Check forvoltage.3. Turn MASTER switch OFF(TM 9--2350--292--10).Repair (WP 0290 00) orreplace (WP 0291 00)harness 2W601. Verifyfault is corrected.DIs 24 V dc present at both checks?noyes1. Disconnect harness 2W601 J1 from harness2W602 P1.2. Reconnect harness 2W601 P1 to accessorycontrol panel.3. Turn MASTER switch ON(TM 9--2350--292--10).4. Place red multimeter lead on harness 2W601J1 socket C and D (one at a time) while holdingblack lead to ground. Check for voltage.5. Turn MASTER swtich OFF(TM 9--2350--292--10).Repair (WP 0290 00) orreplace (WP 0291 00)harness 2W601. Verifyfault is corrected.