TM 9--2350--292--20--1
0180 00--2
WINCH DRUM MALFUNCTION INDICATOR FAILS TO LIGHT WHEN WINCH
DRUM MALFUNCTIONS -- CONTINUED
0180 00
C
Is 24 V dc present at both checks?
CONTINUED FROM STEP B
no
yes
CONTINUED ON NEXT PAGE
1. Disconnect harness 2W602 lead 10
connectors from winch warning limit
switches.
2. Turn MASTER switch ON
(TM 9--2350--292--10).
3. Place multimeter red lead in harness 2W602
lead 10 connector (one at a time) while
holding black lead to ground. Check for
voltage.
4. Turn MASTER switch OFF
(TM 9--2350--292--10).
Go to Step G.
D
Is continuity present at both checks?
no
yes
1. Disconnect harness 2W602 P1 from harness
2W601 J1.
2. Place one multimeter lead in inhaul switch
lead 10 connector and other lead on harness
2W602 P1 pin F.
3. Place one multimeter lead in outhaul switch
lead 10 connector and other lead on harness
2W602 P1 pin E. Check for continuity.
Repair (WP 0290 00) or
replace (WP 0292 00)
harness 2W602. Verify
fault is corrected.