TM 9--2350--292--20--10181 00--5PAYOUT LIMIT INDICATOR FAILS TO LIGHT WHEN LESS THAN FOURWRAPS OF WIRE ROPE ARE LEFT ON DRUM -- CONTINUED0181 00IIs continuity present?CONTINUED FROM STEP HnoyesPlace one multimeter lead on terminal junction T13terminal G and other lead on terminal junction T13terminal B. Check for continuity.Replace terminal junctionT13 (WP 0244 00).Verify fault is corrected.JIs continuity present?noyesPlace one multimeter lead on terminal junction T13terminal B and other lead on diode T7 terminal D.Check continuity.Repair (WP 0290 00) orreplace (WP 0244 00)lead 375 from terminaljunction to diode. Verifyfault is corrected.CONTINUED ON NEXT PAGEKIs resistance low with red lead on terminal D and highwith red lead on terminal A?1. Place red multimeter lead on diode T7 terminalD and black lead on diode T7 terminal A.Check resistance.2. Place red multimeter on diode T7 terminal Aand black led on diode T7 terminal D. Checkresistance.yesnoReplace diode T7(WP 0244 00). Verifyfault is corrected.
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business