TM 9--2350--292--20--1
0187 00--80
0187 00
PREVENTIVE MAINTENANCE CHECKS AND SERVICES INCLUDING
LUBRICATION INSTRUCTIONS -- CONTINUED
TABLE 3 PREVENTIVE MAINTENANCE CHECKS AND SERVICES
INCLUDING LUBRICATION INSTRUCTIONS, SEMIANNUALLY -- CONTINUED
ITEM
NO.
NOT FULLY
MISSION
CAPABLE
IF:
PROCEDURE
LOCATION
ITEM TO
CHECK/
SERVICE
INTERVAL
SEMIANNUALLY
INTERIOR
3
Brakes --
Continued
f. If accumulator charge pressure reading
when shown on gauge (7) is in operation
range, turn valve (6) counterclockwise to
seal accumulator (3) input port. If
accumulator pressure reads below
operational range found in Temperature
Vs. Pressure chart, refer to WP 0373 00
for system charging.
g. Open bleeder valve (4) to bleed hoses
on charging device (2).
h. Disconnect charging device (2) from
accumulator (3), then replace nitrogen
valve cap (1) on accumulator (3).
i. Install subfloor plate #16
(WP 0454 00).
4
7
2
1
6
3