TM 9--2350--292--20--1
0187 00--105
0187 00
PREVENTIVE MAINTENANCE CHECKS AND SERVICES INCLUDING
LUBRICATION INSTRUCTIONS -- CONTINUED
TABLE 3 PREVENTIVE MAINTENANCE CHECKS AND SERVICES
INCLUDING LUBRICATION INSTRUCTIONS, SEMIANNUALLY -- CONTINUED
ITEM
NO.
NOT FULLY
MISSION
CAPABLE
IF:
PROCEDURE
LOCATION
ITEM TO
CHECK/
SERVICE
INTERVAL
SEMIANNUALLY
INTERIOR
18
Personnel
Heater
a. Service fuel filter (1) (WP 0534 00).
Do not operate personnel heater
with any evidence of a fuel leak.
b. Check operation
WARNING
Any leaks.
Heater does
not operate.
Any loose or
missing
components.
(TM 9--2350--292--10).
c. Inspect heater fuel lines and
connections (2) and exhaust (3) for
leakage.
4
4
3
5
2
1
2
d. Tighten loose hose clamps (4), fuel
lines and connections (2) and electrical
connections (5).