TM 9--2350--292--20--10187 00--1070187 00PREVENTIVE MAINTENANCE CHECKS AND SERVICES INCLUDINGLUBRICATION INSTRUCTIONS -- CONTINUEDTABLE 3 PREVENTIVE MAINTENANCE CHECKS AND SERVICESINCLUDING LUBRICATION INSTRUCTIONS, SEMIANNUALLY -- CONTINUEDITEMNO.NOT FULLYMISSIONCAPABLEIF:PROCEDURELOCATIONITEM TOCHECK/SERVICEINTERVALSEMIANNUALLYINTERIOR20Gas ParticulateFilter Units andM3 Air HeatersWARNINGa. Inspect gas particulate filter units (1)and M3 air heaters (2) for dents, looseconnections and missing parts.b. Inspect hose assemblies (3) for looseor missing mounting hardware, damageand deterioration.c. Inspect cable assemblies (4) forloose connections, damaged insulationand broken or damaged terminals.Gasparticulatefilter does notoperate.M3 heaterproducesheat before10 minutes ofoperation,FORWARD33NOTEM3 heaters must operate for10--15 minutes before warm airis felt at stations.d. Operate gas particulate filter units (1)and M3 air heaters (2)(TM 9--2350--292--10).e. Check air flow at each station.f. Check for warm air at each station.g. Shut off gas particulate filter units (1)and turn M3 air heaters (2) switch to off(TM 9--2350--292--10).doesnotproduce heatat all stations,anydamaged,worn ormissingcomponents.442413334