TM 9--2350--292--20--10012 00--4AUXIILIARY POWER UNIT FUEL SOLENOID FAILS TO ENERGIZE --CONTINUED0012 00CONTINUED FROM STEP CIs 24 V dc present?1. Reconnect harness 4W700 P1.2. Open air intake grilles above batterycompartment (TM 9--2350--292--10).3. Disconnect harness 3W702 P1 at bulkheaddisconnect.4. Turn MASTER switch and FUEL SHUT OFFswitch ON (TM 9--2350--292--10).5. Place multimeter red lead on bulkheadreceptacle pin F and black lead to ground.Check for voltage.6. Turn MASTER switch OFF(TM 9--2350--292--10).HIs 24 V dc present?1. Reconnect harness 3W702 P1 to bulkheaddisconnect.2. Disconnect harness 3W711 P1 at APU enginedisconnect.3. Turn MASTER switch ON(TM 9--2350--292--10).4. Place multimeter red lead in harness 3W702 J1socket B and black lead to ground. Check forvoltage.5. Turn MASTER switch OFF(TM 9--2350--292--10)InoRepair (WP 0290 00) orreplace (WP 0311 00)harness 3W702. Verify faultis corrected.yesnoyesRepair (WP 0290 00) orreplace (WP 0332 00)harness 4W700. Verifyfault is corrected.Fault corrected.END OF TASK