TM 9--2350--292--20--2
0627 00--2
AUXILIARY POWER UNIT FUEL PUMP AND RELAY BOX MOUNTING
BRACKET, OIL DRAIN LINES BRACKET AND WIRING HARNESS BRACKET
REPLACEMENT (HATZ) CONTINUED
0627 00
Removal--Continued
3. Remove two screws (9), two lockwashers (10) and isolator mounting bracket (11) from APU. Discard lockwash-
ers.
4. Remove four self--locking nuts (12), four screws (13) and resilient mount (14) from brace (15). Discard self--lock-
ing nuts.
5. Remove screw (16), lockwasher (17), flat washer (18), brace (15) and wiring harness bracket (19) from APU. Dis-
card lockwasher.
6. Remove eight self--locking nuts (20), eight screws (21) and two resilient mounts (22) from bracket (23). Discard
self--locking nuts.
7. Remove two screws (24), two lockwashers (25), two flat washers (26) and bracket (23) from APU. Discard lock-
washers.
8. Inspect all parts for damage and replace as required.
16
9
10
11
17
18
12
13
14
15
19
20
21
22
23
24
25
26