TM 9--2350--292--20--20642 00--2AUXILIARY POWER UNIT WIRING HARNESS 3W704 REPLACEMENT --CONTINUED0642 00Installation1. Connect wiring harness 3W704 wire 493 (6) at wire junction of lead 3W705 (7) for high air temperature switch.2. Connect wiring harness 3W704 wire 420A (4) to low oil pressure switch (5) terminal with screw (3).3. Connect wiring harness 3W704 wire 420 (1) to oil pressure sending unit (2) terminal.4. Apply adhesive to all exposed electrical terminals.Figure 3461245WIRE420AWIRE420WIRE493673NOTEFOLLOW--ON MAINTENANCE:Install APU wiring harness cable clamps (WP 0592 00)END OF TASK