TM 9--2350--292--20--2
0645 00--2
AUXILIARY POWER UNIT LEAD ASSEMBLY 3W705 REPLACEMENT (HATZ)
-- CONTINUED
0645 00
Installation
1. Connect wiring harness 3W705 (3) to wiring harness 3W704 lead 493 (7).
2. Pull wiring harness 3W705 (3) through new grommet (5) and insert grommet (5) into air duct bracket (6).
3. Attach wiring harness 3W705 (3) to thermostatic switch (4), using new lockwasher (2) and nut (1).
4. Apply adhesive to all exposed electrical terminals.
5
3
7
3
4
1
2
6
NOTE
FOLLOW--ON MAINTENANCE:
Install airflow deflectors (TM 9--2815--250--24&P)
Install APU in vehicle (WP 0587 00)
END OF TASK