TM 9--2350--292--20--2
0646 00--2
AUXILIARY POWER UNIT LEAD ASSEMBLY 3W706 REPLACEMENT --
CONTINUED
0646 00
Installation
1. Connect wiring harness 3W711 wire 62 (9) and lead assembly 3W706 (5) to generator terminal B+ (10) with new
self--locking nut (7) and flat washer (8).
2. After generator leads are installed, apply adhesive to exposed terminal.
3. Install lead assembly 3W706 (5) to relay terminal A1 (6) with screw (1), two new lockwashers (2), new lockwasher
(3) and nut (4).
Figure 348
10
9
5
8
7
6
1
2
2
3
4
5
NOTE
FOLLOW--ON MAINTENANCE:
Install APU into vehicle (WP 0587 00)