TM 9--2350--292--20--2
0667 00--25
DEEP WATER FORDING KIT -- CONTINUED
0667 00
Installation--Continued
APPLICATION OF NON--HYGROSCOPIC TAPE (ELECTROMAGNETIC CLUTCH AND HYDRAULIC RESERVOIR)
1. Open subfloor access door (1).
2. Tape bayonet gauge (2) and vent (3) with waterproof tape (12477548--7). Apply adhesive sealant (MIL--A--46106
11EBN) to tape.
3. Close subfloor access door (1).
4. Remove two screws (4), two flat washers (5) and open hydraulic reservoir access plate (6).
5. Tape fill cap (7) and bayonet gauge (8) with waterproof tape (12477548--7). Apply adhesive sealant
(MIL--A--46106 11EBN) to tape.
6. Close hydraulic reservoir access plate (6) and secure with two screws (4) and two flat washers (5).
Figure 355
1
2
3
4
5
6
7
8