TM 9--2350--292--20--2
0667 00--20
DEEP WATER FORDING KIT -- CONTINUED
0667 00
Installation--Continued
ELECTRICAL CONNECTIONS IN ENGINE COMPARTMENT
1. If not already opened or removed, open left side engine deck access doors and remove left side engine deck
grilles (TM 9--2350--292--10) to gain access to electrical connections in engine compartment.
2. Remove voltage regulator cover (WP 0239 00) to gain access to NATO slave connections.
3. In the following procedures, clean and dry all electrical and ground connections prior to application of sealant.
WARNING
Do not seal battery cap vents. Buildup of battery gas
may cause batteries to rupture, spilling acid which may
cause personnel injury.
4. Apply adhesive sealant (MIL--A--46146 11EWN ) to all positive and negative battery terminals and ground connec-
tions (1), to main engine ground connection (2) and to NATO slave connections (3).
5. Install voltage regulator cover (WP 0239 00).
102
Figure 355
3
3
3
2
1
1
1
1
1
1