TM 9--2350--292--20--20686 00--4BOOM SHUT OFF VALVE TRANSDUCERS AND RELATED PARTSREPLACEMENT -- CONTINUED0686 00Removal--Continued6. Remove wiring harness 4W504 connector P2 (11) from transducer 4MT543 (12).7. Remove transducer 4MT543 (12) with hose (13) from adapter (14) then remove hose (13) from transducer4MT543 (12).8. Remove hose (15) from tee (16).9. Remove tee (16) and adapter (14) from boom shut off valve (8).10. Remove three preformed packings (17, 18 and 19) from tee (16), preformed packing (20) from hose (13) and pre-formed packing (21) from adapter (14). Discard preformed packing.11. Inspect all parts for damage and replace as required.NOTE;BOOM SHUT OFF VALVEHOSES AND FITTINGSREMOVED FOR CLARITY11121381514161718192021