TM 9--2350--292--20--2
0687 00--3
HOIST WINCH TRANSDUCERS AND RELATED PARTS REPLACEMENT --
CONTINUED
0687 00
Removal--Continued
1. Remove wiring harness 4W503 connector P12 (1) from transducer 4MT544 (2).
2. Remove transducer 4MT544 (2) with straight swivel adapter (3) from elbow (4) then remove straight swivel adapt-
er (3) from transducer 4MT544 (2).
3. Remove elbow (4) from hoist winch motor test port (5).
4. Remove preformed packings (6 and 7) from straight swivel adapter (3) and elbow (4). Discard preformed pack-
ings.
1
2
3
4
5
6
7
NOTE:
HOIST WINCH
HOSES AND FITTINGS
REMOVED FOR CLARITY