Removal--Continued
WARNING
Hydraulic system pressure is rated 4450 psi. Do not
torque hydraulic fittings or perform removal procedures
when hydraulic system is pressurized. Discharging
system pressure before performing any maintenance
procedures will avoid injury to personnel.
Eye protection will be worn when performing mainte-
nance procedures on all hydraulic components to avoid
injury to personnel.
CAUTION
Cap all hydraulic lines and plug all hydraulic ports to
prevent contamination. Failure may result in damage to
hydraulic system.
All serviceable components must be placed in plastic
bags to prevent contamination of hydraulic system during
installation.
NOTE
All hydraulic lines and components must be tagged
before removal for identification during installation.
Place rags under hydraulic connections to catch any
hydraulic fluid that spills during maintenance. Dispose of
fluid soaked rags in accordance with standard operating
procedure.