TM 9--2350--292--20--20687 00--2HOIST WINCH TRANSDUCERS AND RELATED PARTS REPLACEMENT --CONTINUED0687 00Removal--ContinuedWARNINGHydraulic system pressure is rated 4450 psi. Do nottorque hydraulic fittings or perform removal procedureswhen hydraulic system is pressurized. Dischargingsystem pressure before performing any maintenanceprocedures will avoid injury to personnel.Eye protection will be worn when performing mainte-nance procedures on all hydraulic components to avoidinjury to personnel.CAUTIONCap all hydraulic lines and plug all hydraulic ports toprevent contamination. Failure may result in damage tohydraulic system.All serviceable components must be placed in plasticbags to prevent contamination of hydraulic system duringinstallation.NOTEAll hydraulic lines and components must be taggedbefore removal for identification during installation.Place rags under hydraulic connections to catch anyhydraulic fluid that spills during maintenance. Dispose offluid soaked rags in accordance with standard operatingprocedure.
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business