TM 9--2350--292--20--2
0551 00--2
HYDRAULIC FILTER MANIFOLD CHECK VALVE AND PRESSURE SENSING
VALVE REPLACEMENT -- CONTINUED
0551 00
Removal
WARNING
CAUTION
Cap all hydraulic lines and plug all hydraulic ports to pre-
vent contamination. Failure to comply may result in dam-
age to the hydraulic system.
1. Remove check valve (1) with two preformed packings (2) and packing retainer (3) from filter manifold (4). Discard
preformed packings and packing retainer.
2. Remove pressure sensing valve (5) with three preformed packings (6) and four packing retainers (7) from filter
manifold (4). Discard preformed packings and packing retainers.
3. Inspect parts for damage and replace as required.
Figure 300