TM 9--2350--292--20--20562 00--3HYDRAULIC CONTROL VALVES REPLACEMENT -- CONTINUED0562 00InstallationWARNING1. Clean all metal surfaces with cleaning cloth and dry--cleaning solvent prior to installation.2. Apply a thin coating of lubricant to all new preformed packings.3. Install pilot control valve (28), two new preformed packings (30), adapter (29) and two new preformed packings(31) on manifold assembly (5) with two screws (27).4. Install pilot control valve (23), two new preformed packings (26), adapter (24) and two performed packings (25) onmanifold assembly (5) with two screws (22).5. Install boom DCV safety valve (20) and four new preformed packings (21) on manifold assembly (5) with fourscrews (19).6. Install auxiliary winch DCV valve (16), four new preformed packings (18) and five new preformed packings (17) onmanifold assembly (5) with four screws (15).15161718519202122232624253027282931