TM 1-1680-320-13&P
0016 00
WARNING
Activation of FULL OUT LIMIT SWITCH (SW5), overriding SW1 and SW2,
allows drum to turn continuously until released. Damage will occur if cable
retainer finger is allowed to roll over cable. To prevent roll over, do not extend
cable beyond one wrap remaining on drum assembly. Operator shall monitor
through winch assembly opening.
9. Locate SW5 on underside of limit switch drive assembly. Depress SW5, using hex wrench or equivalent, and
hold.
10. Extend hoist cable until one wrap remains on drum, with cable retaining finger setscrew at 12 o'clock position.
11. Disconnect electrical power.
0016 00-4