TM 9-2350-256-20-1
0053 00
CORRECTIVE ACTION Continued
8.
three screws (1). Open air inlet doors (TM 9-2350-256-10). Disconnect wire 48 pin A from bulkhead
to master relay wiring harness. Place red multimeter lead in socket and black lead to ground. Turn
MASTER switch on and check for voltage. If voltage is present repair or replace switch panel, radio,
and bilge pump to bulkhead wiring harness (see WP 0202 00). If voltage is not present, troubleshoot
END OF WORK PACKAGE