TM 9-2350-256-20-1
0054 00
CORRECTIVE ACTION Continued
2.
Place red lead of multimeter on pin A of voltage regultor and black lead to ground. Turn MASTER
switch on, start engine, open generator cutout switch and check for voltage. Turn engine and MASTER
switch OFF, and close generator cutout switch. If voltage is present, go to step 7. If voltage is not
present, replace main engine regulator (see WP 0154 00).
3.
Disconnect electrical accessories panel wiring harness from electrical accessories panel. Place red lead
of multimeter in socket C of wire 1 and black lead to ground. Turn MASTER switch on and check for
voltage. Turn MASTER switch OFF. If voltage is present, go to step 4. If voltage is not present, go to
step 5.
0054 00-3