TM 9-2350-256-20-1
0054 00
CORRECTIVE ACTION Continued
10. Remove four screws (4), four lockwashers (5), and release accessories panel (6). Disconnect wire 1
(from socket D) from generator cutout switch. Place red lead of multimeter in wire 1 and black lead
to ground. Turn MASTER switch on and check for voltage. Turn MASTER switch OFF. If voltage is
present, go to step 11. If voltage is not present repair/replace wire 1 of bilge pump main power wiring
harness from socket D (see WP 0233 00).
11. Reconnect wire 1 (from socket D) to generator cutout switch. Disconnect wire 1 (from socket C) from
generator cutout switch. Place red lead of multimeter on generator cutout switch and black lead to
ground. Turn MASTER switch on, open generator cutout switch and check for voltage. Turn MASTER
switch OFF, close generator cutout switch. If voltage is present, repair/replace wire 1 of bilge pump
main power wiring harness (see WP 0233 00). If voltage is not present, replace generator cutout switch
(see WP 0158 00).
END OF WORK PACKAGE
0054 00-7/8 blank