TM 9-2350-256-20-1
0054 00
CORRECTIVE ACTION Continued
8.
Remove powerplant (see WP 0098 00). Disconnect wire 2 from generator positive terminal B. Install
groundhop, from positive terminal B to suitable ground. Turn MASTER switch on, start engine,
open generator cutout switch. If voltage is not present, repair/replace wire 2 of generator power lead
assembly (see WP 0185 00). Reconnect wire 2 to positive terminal B. If voltage is present, replace
engine generator (see WP 0150 00).
9.
Reconnect bulkhead to engine wiring harness and starter relay wiring harness to bulkhead disconnect.
Remove engine deck (see WP 0336 00). Disconnect bulkhead to engine bracket and rear fuel tank
1 and black lead to ground. Turn MASTER switch on, start engine, open generator cutout switch and
check for voltage. Turn engine and MASTER switch OFF and close generator cutout switch. If voltage
is present, repair/replace wire 1 of bulkhead to engine bracket and rear fuel tank transmitter wiring
harness (see WP 0222 00). If voltage is not present, go to step 10.
0054 00-6