TM 9-2350-256-20-1
0055 00
CORRECTIVE ACTION Continued
6.
Reconnect wire 2 of engine disconnect to engine generator relay lead to engine generator relay. Remove
engine deck (see WP 0336 00). Disconnect generator power lead assembly from engine disconnect.
Place red lead of multimeter in socket A of wire 2 and black lead to ground. Turn MASTER switch on,
start engine, open generator cutout switch and check for voltage. Turn engine and MASTER switch
OFF, and close generator cutout switch. If voltage is present, repair/replace wire 2 of engine disconnect
to engine generator relay lead (see WP 0211 00). If voltage is not present, go to step 7.
7.
Reconnect generator power lead assembly to engine disconnect. Remove powerplant (see WP 0098
00). Disconnect wire 2
from generator, positive terminal B.
Place red lead of
multimeter on
terminal
of generator and black lead to ground. Turn MASTER switch on, start engine, open generator cutout
switch and check for voltage. Turn engine and MASTER switch OFF, and close generator cutout
switch. If voltage is present, repair/replace generator power lead assembly (see WP 0185 00). If
voltage is not present, replace engine generator (see WP 0150 00).
0055 00-6