TM 9-2350-256-20-1
0058 00
CORRECTIVE ACTION Continued
5.
Place red lead of multimeter on pin N of wire 10/15 and black lead to ground. Turn MASTER switch
on and check for voltage. Turn MASTER switch OFF. If voltage is present, go to step 6. If voltage is
not present, go to step 8.
6.
Reconnect switch panel to gage panel and miscellaneous switches wiring harness to main switch panel.
Disconnect wire 25/27 from 15 A circuit breaker. Place red lead of multimeter on circuit breaker
terminal and black lead to ground. Turn MASTER switch on and check for voltage. Turn MASTER
switch OFF. If voltage is present, repair/replace wire 27 of main lighting and B.O. selector switch
wiring harness (see WP 0218 00). If voltage is not present, go to step 7.
0058 00-6