TM 9-2350-256-20-2
0189 00
3.
Remove three leads (3, 4, and 5) from starter solenoid (16) by removing two nuts (17) and two lockwashers (18).
4.
Disconnect connector (6) from starter module low voltage protective system (19).
5.
Disconnect three connectors (2, 7, and 8) from main engine wiring harness (20). Remove wiring harness (21).
Disassembly
1.
Disassemble wiring harness (21) (see WP 0255 00 thru 0264 00, as appropriate).
Assembly
Assemble wiring harness (21) (see WP 0255 00 thru 0264 00, as appropriate).
1.
Installation
1.
Connect three connectors (2, 7, and 8) to main engine wiring harness (20).
2.
Connect connector (6) to starter module low voltage protective system (19).
3.
Install three leads (3, 4, and 5) to starter solenoid (17) using lockwasher (18) and nut (19).
4.
Install wiring harness connector (1) to engine disconnect (12) using four nuts (15), four lockwashers (14), and four screws
(13).
5.
Install clamp (9) using lockwasher (11) and screw (10).
NOTE
Follow-on maintenance: Install powerplant (see WP 0098 00).
END OF WORK PACKAGE
0189 00-3/4 blank