TM 9-2350-256-20-2
0190 00
7.
Disconnect two connectors (8 and 9) from batteries (23) by pulling back rubber insulator (24) and removing bolt (25) and
nut (26).
8.
Disconnect connector (10) from bulkhead to APU, master relay, and rigger's lights wiring harness (27).
9.
Disconnect connector (11) and lead (12) by removing screw (28) from APU voltage regulator (29).
Disassembly
1.
Disassemble wiring harness (see WP 0255 00 thru 0264 00, as appropriate).
Assembly
1.
Assemble wiring harness (see WP 0255 00 thru 0264 00, as appropriate).
0190 00-4