TM 9-2350-256-20-2
UNIT MAINTENANCE
RECOVERY VEHICLE, FULL TRACKED: MEDIUM, M88A1
TERMINAL-TYPE CABLE CONNECTOR REPAIR
INITIAL SETUP:
Tools and Special Tools
WARNING
Be certain MASTER switch is OFF when working on electrical system to avoid electrical shock and
burns.
Repair or Replacement
1.
Strip cable (1) insulation equal to depth of terminal (2) well.
2.
Slide insulator (3) over cable (1).
3.
Insert cable into terminal (2) well and crimp.
4.
Slide insulator (3) over crimped end of terminal (2).
END OF WORK PACKAGE