TM 9-2350-256-20-2
UNIT MAINTENANCE
RECOVERY VEHICLE, FULL TRACKED: MEDIUM, M88A1
MALE CABLE CONNECTOR REPAIR
INITIAL SETUP:
Tools and Special Tools
WARNING
Be certain MASTER switch is OFF when working on electrical system to avoid electrical shock and
burns.
Repair or Replacement
1.
Strip cable (1) insulation equal to depth of terminal (2) well.
2.
Slide shell (3) over cable (1).
3.
Insert cable into terminal (2) well and crimp.
4.
Place C-washer (4) over cable (1) at crimped junction and slide shell (3) over C-washer and terminal (2).
END OF WORK PACKAGE