CHAPTER 14: MAINTENANCE OF MBA3 GAS/PARTICULATE FILTER UNIT TM 9-2350-256-2014-1 REPLACE/REPAIR MBA3 FILTER UNIT SYSTEM-Continued11Place ground wire (6) between frame assembly (21) and M2A2 air purifier (3). Install M2A2 air purifier in frameassembly by closing catch assembly (22).12Install two clamps (13) and clamp (15) each with screw (19) and new lockwasher (20).13Connect mechanic's hose (14) between manifold of M2A2 air purifier (3) and clamp (15). Secure hose with sixclamps (16), each held by screw (17) and new lockwasher (18).14Connect rigger's hose (11) and commander's hose (12) between manifold of M2A2 air purifier (3) and clamps (13).15Install circuit breaker and switch assembly (2) with two screws (9) and two new lockwashers (10).16Connect ground wire (6) on M2A2 air purifier (3) with screw (7) and new lockwasher (8).17Connect cable assembly (4) between circuit breaker and switch assembly (2) and dome light (5).18Connect cable assembly (1) between circuit breaker and switch assembly (2) and M2A2 air purifier (3).14-8