TM 9-2350-256-20
e. TEST
1
Move spring clip (49) from M2A2 air purifier air
intake holes. Perform test as instructed in operator's
manual TM 9-2350-256-10 located in airflow tester
container.
2
Replace spring clip (49) at completion of test
14-2 REPLACE/REPAIR M8A3 FILTER UNIT M2A2 AIR PURIFIER
THIS TASK COVERS
a.
Removal
b.
Disassembly
c.
Assembly
d.
Installation
INITIAL SET-UP
Parts:
Lockwashers (4) (Appendix G, item 128)
a.
REMOVAL
WARNING
After suspected NBC exposure of this
vehicle, all air filter media shall be
handled only by personnel wearing full
NBC-protective equipment.
NOTE
The following procedures apply to
either right or left M2A2 air purifier.
1
Disconnect cable assembly (1) from M2A2 air purifier
(2).
2
Remove ground wire (3) from M2A2 air purifier (2) by
removing screw (4) and lockwasher (5).
3
Tag and disconnect hoses (6).
4
Remove M2A2 air purifier (2) from frame assembly
(7) by opening catch assembly (8).
14-9