TM 9-2350-256-20e. TEST1Move spring clip (49) from M2A2 air purifier airintake holes. Perform test as instructed in operator'smanual TM 9-2350-256-10 located in airflow testercontainer.2Replace spring clip (49) at completion of test14-2 REPLACE/REPAIR M8A3 FILTER UNIT M2A2 AIR PURIFIERTHIS TASK COVERSa.Removalb.Disassemblyc.Assemblyd.InstallationINITIAL SET-UPParts:Lockwashers (4) (Appendix G, item 128)a.REMOVALWARNINGAfter suspected NBC exposure of thisvehicle, all air filter media shall behandled only by personnel wearing fullNBC-protective equipment.NOTEThe following procedures apply toeither right or left M2A2 air purifier.1Disconnect cable assembly (1) from M2A2 air purifier(2).2Remove ground wire (3) from M2A2 air purifier (2) byremoving screw (4) and lockwasher (5).3Tag and disconnect hoses (6).4Remove M2A2 air purifier (2) from frame assembly(7) by opening catch assembly (8).14-9