SECTION V: TROUBLESHOOTINGTM 9-2350-256-20WARNINGRemove all jewelry such as rings, dogtags, bracelets, etc. If jewelry contacts ametal surface a direct short may result ininstant heating of tools, damage toequipment, and injury or death topersonnel.ARemove three screws (1), three lockwashers (2), twoscrews (3), two lockwashers (4), and ground strap (5)and release gage panel (6) from mounting brackets.Remove gage panel to bulkhead wiring harness fromgage panel. Place red lead of multimeter on socket Kof wire 27 and black lead to ground. Turn MASTERswitch on and check for voltage. Turn MASTER switchOFF. If voltage is present, go to step B. If voltage isnot present, troubleshoot power control lever circuit.BReconnect gage panel to bulkhead wiring harness togage panel. Disconnect wire 27C from engine oiltemperature gage. Place red lead of multimeter in wire27C and black lead to ground. Turn MASTER switchon and check for voltage. Turn MASTER switch OFF.If voltage is present, go to step C. If voltage is notpresent, repair/replace wire 27C of gage panel wiringharness (see paragraph 6-44).2-101